CVE-2017-2681
Siemens · published 2017-05-11
Source record Collected from the National Vulnerability Database (NVD)
Description
Description by Siemens AG via the CVE Program.
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Status at the source
- NVD status: Modified
Affected products, as the source lists them
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller | All versions < V4.1.1 Patch04: affected |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 | All versions < V4.2.1 Patch03: affected |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P | All versions < V4.4.0 Patch01: affected |
| Siemens | IE/AS-i Link PN IO | All versions: affected |
| Siemens | IE/PB-Link (incl. SIPLUS NET variants) | All versions < V3.0: affected |
| Siemens | SCALANCE M-800 family (incl. S615, MUM-800 and RM1224) | All versions < V4.03: affected |
| Siemens | SCALANCE W-700 IEEE 802.11n family | All versions < V6.1: affected |
| Siemens | SCALANCE X-200 family (incl. SIPLUS NET variants) | All versions < V5.2.2: affected |
| Siemens | SCALANCE X-200IRT family (incl. SIPLUS NET variants) | All versions < V5.4.0: affected |
| Siemens | SCALANCE X-300 family (incl. X408 and SIPLUS NET variants) | All versions < V4.1.0: affected |
| Siemens | SCALANCE X408 family | All versions < V4.1.0: affected |
| Siemens | SCALANCE X414 | All versions < V3.10.2: affected |
| Siemens | SCALANCE XM-400 family | All versions < V6.1: affected |
| Siemens | SCALANCE XR-500 family | All versions < V6.1: affected |
| Siemens | SIMATIC CM 1542-1 | All versions < V2.0: affected |
| Siemens | SIMATIC CM 1542SP-1 | All versions < V1.0.15: affected |
| Siemens | SIMATIC CP 1243-1 (incl. SIPLUS variants) | All versions < V2.1.82: affected |
| Siemens | SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) | 0 – before *: affected |
| Siemens | SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) | All versions: affected |
| Siemens | SIMATIC CP 1243-8 IRC | All versions < V2.1.82: affected |
| Siemens | SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants) | All versions < V1.0.15: affected |
| Siemens | SIMATIC CP 1543-1 (incl. SIPLUS variants) | All versions < V2.1: affected |
| Siemens | SIMATIC CP 1543SP-1 (incl. SIPLUS variants) | All versions < V1.0.15: affected |
| Siemens | SIMATIC CP 1604 | All versions < V2.7: affected |
| Siemens | SIMATIC CP 1616 | All versions < V2.7: affected |
| Siemens | SIMATIC CP 343-1 (incl. SIPLUS variants) | All versions < V3.1.3: affected |
| Siemens | SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) | All versions: affected |
| Siemens | SIMATIC CP 343-1 Lean (incl. SIPLUS variants) | All versions < V3.1.3: affected |
| Siemens | SIMATIC CP 443-1 (incl. SIPLUS variants) | All versions < V3.2.17: affected |
| Siemens | SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) | All versions < V3.2.17: affected |
| Siemens | SIMATIC CP 443-1 OPC UA | All versions: affected |
| Siemens | SIMATIC DK-16xx PN IO | All versions < V2.7: affected |
| Siemens | SIMATIC ET 200AL IM 157-1 PN | 0 – before V1.0.2: affected |
| Siemens | SIMATIC ET 200M (incl. SIPLUS variants) | All versions: affected |
| Siemens | SIMATIC ET 200MP IM 155-5 PN BA | 0 – before V4.0.1: affected |
| Siemens | SIMATIC ET 200MP IM 155-5 PN HF | 0 – before V4.2.0: affected |
| Siemens | SIMATIC ET 200MP IM 155-5 PN ST | 0 – before V4.1.0: affected |
| Siemens | SIMATIC ET 200pro IM 154-3 PN HF | 0 – before *: affected |
| Siemens | SIMATIC ET 200pro IM 154-4 PN HF | 0 – before *: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN BA | 0 – before *: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN HF | 0 – before V4.2.0: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN HS | 0 – before V4.0.1: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST | 0 – before V4.1.0: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST BA | 0 – before V4.1.0: affected |
| Siemens | SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 4AO U/I 4xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN: IO-Link Master | All versions: affected |
| Siemens | SIMATIC ET200S (incl. SIPLUS variants) | All versions: affected |
| Siemens | SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants) | All versions < V15.1: affected |
| Siemens | SIMATIC MV420 SR-B | 0 – before V7.0.6: affected |
| Siemens | SIMATIC MV420 SR-B Body | 0 – before V7.0.6: affected |
| Siemens | SIMATIC MV420 SR-P | 0 – before V7.0.6: affected |
| Siemens | SIMATIC MV420 SR-P Body | 0 – before V7.0.6: affected |
| Siemens | SIMATIC MV440 HR | 0 – before V7.0.6: affected |
| Siemens | SIMATIC MV440 SR | 0 – before V7.0.6: affected |
| Siemens | SIMATIC MV440 UR | 0 – before V7.0.6: affected |
| Siemens | SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) | All versions < V4.0: affected |
| Siemens | SIMATIC RF650R | All versions < V3.0: affected |
| Siemens | SIMATIC RF680R | All versions < V3.0: affected |
| Siemens | SIMATIC RF685R | All versions < V3.0: affected |
| Siemens | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) | All versions < V4.2.1: affected |
| Siemens | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) | All versions < V2.1: affected |
| Siemens | SIMATIC S7-1500 Software Controller | All versions < V2.1: affected |
| Siemens | SIMATIC S7-200 SMART | All versions < V2.3: affected |
| Siemens | SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) | 0 – before V3.X.14: affected |
| Siemens | SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) | 0 – before V6.0.7: affected |
| Siemens | SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) | 0 – before V6.0.6: affected |
| Siemens | SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) | 0 – before V7.0.2: affected |
| Siemens | SIMATIC S7-410 CPU family (incl. SIPLUS variants) | All versions < V8.2: affected |
| Siemens | SIMATIC TDC CP51M1 | 0 – before V1.1.8: affected |
| Siemens | SIMATIC TDC CPU555 | 0 – before V1.1.1: affected |
| Siemens | SIMATIC Teleservice Adapter IE Advanced | All versions: affected |
| Siemens | SIMATIC Teleservice Adapter IE Basic | All versions: affected |
| Siemens | SIMATIC Teleservice Adapter IE Standard | All versions: affected |
| Siemens | SIMATIC WinAC RTX 2010 | All versions < V2010 SP3: affected |
| Siemens | SIMATIC WinAC RTX F 2010 | All versions < V2010 SP3: affected |
| Siemens | SIMOCODE pro V PROFINET (incl. SIPLUS variants) | All versions < V2.0.0: affected |
| Siemens | SIMOTION | All versions < V4.5 HF1: affected |
| Siemens | SINAMICS DCM w. PN | All versions < V1.4 SP1 HF5: affected |
| Siemens | SINAMICS DCP w. PN | All versions < V1.2 HF1: affected |
| Siemens | SINAMICS G110M w. PN | All versions < V4.7 SP6 HF3: affected |
| Siemens | SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants) | All versions < V4.7 SP6 HF3: affected |
| Siemens | SINAMICS G130 V4.7 w. PN | All versions < V4.7 HF27: affected |
| Siemens | SINAMICS G130 V4.8 w. PN | All versions < V4.8 HF4: affected |
| Siemens | SINAMICS G150 V4.7 w. PN | V4.7: All versions < V4.7 HF27: affected |
| Siemens | SINAMICS G150 V4.8 w. PN | All versions < V4.8 HF4: affected |
| Siemens | SINAMICS S110 w. PN | All versions < V4.4 SP3 HF5: affected |
| Siemens | SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants) | All versions < V4.7: affected |
| Siemens | SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants) | All versions: affected |
| Siemens | SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants) | All versions < V4.7 HF27: affected |
The source lists more products than DeSpy shows; see the source record.
Products named in NVD's CPE match criteria (50)
cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_dk-16xx_pn_io_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ie\/pb-link_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ie\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_teleservice_adapter_standard_modem_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:pn\/pn_coupler_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*
DeSpy has not checked any unit, hardware revision or firmware. A product missing here is not a statement that it is unaffected.
Scores, as their sources published them
- CVSS 4.0: 7.1 HIGH — as published by Siemens AG (Secondary)
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1: 6.5 MEDIUM — as published by Siemens AG (Secondary)
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 3.1: 6.5 MEDIUM — as published by NIST (Primary)
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 2.0: 6.1 MEDIUM — as published by NIST (Primary)
AV:A/AC:L/Au:N/C:N/I:N/A:C - SSVC — CISA's assessment (SSVC 2.0.3, CISA Coordinator): Exploitation: none · Automatable: no · Technical impact: partial
DeSpy does not score records. These are the sources' own values.
Weaknesses
Sources
References the source lists
- http://www.securityfocus.com/bid/98369
- http://www.securitytracker.com/id/1038463
- https://cert-portal.siemens.com/productcert/html/ssa-293562.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf
- https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf
- http://www.securityfocus.com/bid/98369
- http://www.securitytracker.com/id/1038463
- https://cert-portal.siemens.com/productcert/html/ssa-293562.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf
- https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf
Source dates: published 2017-05-11, last changed 2026-06-17. DeSpy's copy of this version is dated 2026-09-28.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.
CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.