CVE-2019-10936
Siemens · published 2019-10-10
Source record Collected from the National Vulnerability Database (NVD)
Description
Description by Siemens AG via the CVE Program.
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Status at the source
- NVD status: Modified
Affected products, as the source lists them
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller | 0 – before *: affected |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 | 0 – before *: affected |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P | All versions < V4.6 Patch 01: affected |
| Siemens | SIMATIC CFU PA | 0 – before V1.2.0: affected |
| Siemens | SIMATIC ET 200AL IM 157-1 PN | All versions: affected |
| Siemens | SIMATIC ET 200M (incl. SIPLUS variants) | All versions: affected |
| Siemens | SIMATIC ET 200MP IM 155-5 PN BA | 0 – before V4.3.0: affected |
| Siemens | SIMATIC ET 200MP IM 155-5 PN HF | 0 – before V4.4.0: affected |
| Siemens | SIMATIC ET 200MP IM 155-5 PN ST | 0 – before *: affected |
| Siemens | SIMATIC ET 200MP IM 155-5 PN ST | 0 – before *: affected |
| Siemens | SIMATIC ET 200pro IM 154-3 PN HF | 0 – before *: affected |
| Siemens | SIMATIC ET 200pro IM 154-4 PN HF | 0 – before *: affected |
| Siemens | SIMATIC ET 200pro IM 154-8 PN/DP CPU | All versions < V3.2.17: affected |
| Siemens | SIMATIC ET 200pro IM 154-8F PN/DP CPU | All versions < V3.2.17: affected |
| Siemens | SIMATIC ET 200pro IM 154-8FX PN/DP CPU | All versions < V3.2.17: affected |
| Siemens | SIMATIC ET 200S IM 151-8 PN/DP CPU | All versions < V3.2.17: affected |
| Siemens | SIMATIC ET 200S IM 151-8F PN/DP CPU | All versions < V3.2.17: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN BA | 0 – before *: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) | All versions < V1.2.1: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN HF | 0 – before V4.2.2: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN HS | 0 – before V4.0.1: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST | 0 – before *: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST | 0 – before *: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST BA | 0 – before *: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST BA | 0 – before *: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN/2 HF | 0 – before V4.2.2: affected |
| Siemens | SIMATIC ET 200SP IM 155-6 PN/3 HF | 0 – before V4.2.1: affected |
| Siemens | SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) | 0 – before V2.0: affected |
| Siemens | SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 4AO U/I 4xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 | All versions: affected |
| Siemens | SIMATIC ET200ecoPN: IO-Link Master | All versions: affected |
| Siemens | SIMATIC ET200S (incl. SIPLUS variants) | All versions: affected |
| Siemens | SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants) | 0 – before *: affected |
| Siemens | SIMATIC HMI Comfort Panels (incl. SIPLUS variants) | 0 – before *: affected |
| Siemens | SIMATIC HMI KTP Mobile Panels | 0 – before *: affected |
| Siemens | SIMATIC PN/PN Coupler | All versions < V4.2.1: affected |
| Siemens | SIMATIC PROFINET Driver | All versions < V2.1: affected |
| Siemens | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) | All versions < V4.4.0: affected |
| Siemens | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) | All versions < V2.0: affected |
| Siemens | SIMATIC S7-1500 Software Controller | All versions < V2.0: affected |
| Siemens | SIMATIC S7-300 CPU 314C-2 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-300 CPU 315-2 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-300 CPU 315F-2 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-300 CPU 315T-3 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-300 CPU 317-2 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-300 CPU 317F-2 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-300 CPU 317T-3 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-300 CPU 317TF-3 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-300 CPU 319-3 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-300 CPU 319F-3 PN/DP | All versions < V3.2.17: affected |
| Siemens | SIMATIC S7-400 CPU 412-2 PN V7 | 0 – before V7.0.3: affected |
| Siemens | SIMATIC S7-400 CPU 414-3 PN/DP V7 | 0 – before V7.0.3: affected |
| Siemens | SIMATIC S7-400 CPU 414F-3 PN/DP V7 | 0 – before V7.0.3: affected |
| Siemens | SIMATIC S7-400 CPU 416-3 PN/DP V7 | 0 – before V7.0.3: affected |
| Siemens | SIMATIC S7-400 CPU 416F-3 PN/DP V7 | 0 – before V7.0.3: affected |
| Siemens | SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) | 0 – before V6.0.9: affected |
| Siemens | SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) | 0 – before *: affected |
| Siemens | SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) | All versions < V8.2.2: affected |
| Siemens | SIMATIC TDC CP51M1 | 0 – before V1.1.8: affected |
| Siemens | SIMATIC TDC CPU555 | 0 – before V1.1.1: affected |
| Siemens | SIMATIC WinAC RTX 2010 | All versions < V2010 SP3: affected |
| Siemens | SIMATIC WinAC RTX F 2010 | All versions < V2010 SP3: affected |
| Siemens | SINAMICS DCM | All versions < V1.5 HF1: affected |
| Siemens | SINAMICS DCP | All versions < V1.3: affected |
| Siemens | SINAMICS G110M V4.7 PN Control Unit | All versions < V4.7 SP10 HF5: affected |
| Siemens | SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants) | All versions < V4.7 SP10 HF5: affected |
| Siemens | SINAMICS G130 V4.7 Control Unit | All versions < 4.8: affected |
| Siemens | SINAMICS G150 Control Unit | All versions < 4.8: affected |
| Siemens | SINAMICS GH150 V4.7 Control Unit | All versions: affected |
| Siemens | SINAMICS GL150 V4.7 Control Unit | All versions: affected |
| Siemens | SINAMICS GM150 V4.7 Control Unit | All versions: affected |
| Siemens | SINAMICS S110 Control Unit | 0 – before *: affected |
| Siemens | SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) | 0 – before *: affected |
| Siemens | SINAMICS S150 Control Unit | All versions < 4.8: affected |
| Siemens | SINAMICS SL150 V4.7 Control Unit | All versions < V4.7 HF33: affected |
| Siemens | SINAMICS SM120 V4.7 Control Unit | 0 – before *: affected |
| Siemens | SINUMERIK 828D | All versions < V4.8 SP5: affected |
| Siemens | SINUMERIK 840D sl | All versions < V4.8 SP6: affected |
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF | 0 – before V4.4.0: affected |
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF | 0 – before V4.4.0: affected |
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL | 0 – before V4.4.0: affected |
| Siemens | SIPLUS ET 200MP IM 155-5 PN ST | 0 – before *: affected |
| Siemens | SIPLUS ET 200MP IM 155-5 PN ST | 0 – before *: affected |
| Siemens | SIPLUS ET 200MP IM 155-5 PN ST TX RAIL | 0 – before *: affected |
| Siemens | SIPLUS ET 200MP IM 155-5 PN ST TX RAIL | 0 – before *: affected |
| Siemens | SIPLUS ET 200S IM 151-8 PN/DP CPU | All versions < V3.2.17: affected |
| Siemens | SIPLUS ET 200S IM 151-8F PN/DP CPU | All versions < V3.2.17: affected |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF | 0 – before V4.2.2: affected |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF | 0 – before V4.2.2: affected |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF | 0 – before V4.2.2: affected |
The source lists more products than DeSpy shows; see the source record.
Products named in NVD's CPE match criteria (50)
cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_ba_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ba_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hf_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hs_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_st_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\/2_hf_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\/3_hf_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_pn\/pn_coupler_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1500s_cpu_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1500t_cpu_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*
DeSpy has not checked any unit, hardware revision or firmware. A product missing here is not a statement that it is unaffected.
Scores, as their sources published them
- CVSS 3.1: 7.5 HIGH — as published by Siemens AG (Secondary)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 3.1: 7.5 HIGH — as published by NIST (Secondary)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 2.0: 5 MEDIUM — as published by NIST (Primary)
AV:N/AC:L/Au:N/C:N/I:N/A:P - SSVC — CISA's assessment (SSVC 2.0.3, CISA Coordinator): Exploitation: none · Automatable: yes · Technical impact: partial
DeSpy does not score records. These are the sources' own values.
Weaknesses
Sources
References the source lists
- https://cert-portal.siemens.com/productcert/html/ssa-473245.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-473245.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf
Source dates: published 2019-10-10, last changed 2026-06-17. DeSpy's copy of this version is dated 2026-09-28.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.
CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.