CVE-2019-13946
Siemens · published 2020-02-11
Source record Collected from the National Vulnerability Database (NVD)
Description
Description by Siemens AG via the CVE Program.
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
Status at the source
- NVD status: Modified
Affected products, as the source lists them
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller | 0 – before *: affected |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 | All Versions < V4.5: affected |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P | All Versions < V4.6: affected |
| Siemens | PROFINET Driver for Controller | All Versions < V2.1: affected |
| Siemens | RUGGEDCOM RM1224 family | All versions < V4.3: affected |
| Siemens | SCALANCE M804PB | All versions < V4.3: affected |
| Siemens | SCALANCE M812-1 ADSL-Router | All versions < V4.3: affected |
| Siemens | SCALANCE M812-1 ADSL-Router | All versions < V4.3: affected |
| Siemens | SCALANCE M816-1 ADSL-Router | All versions < V4.3: affected |
| Siemens | SCALANCE M816-1 ADSL-Router | All versions < V4.3: affected |
| Siemens | SCALANCE M826-2 SHDSL-Router | All versions < V4.3: affected |
| Siemens | SCALANCE M874-2 | All versions < V4.3: affected |
| Siemens | SCALANCE M874-3 | All versions < V4.3: affected |
| Siemens | SCALANCE M876-3 | All versions < V4.3: affected |
| Siemens | SCALANCE M876-3 (ROK) | All versions < V4.3: affected |
| Siemens | SCALANCE M876-4 (EU) | All versions < V4.3: affected |
| Siemens | SCALANCE M876-4 (NAM) | All versions < V4.3: affected |
| Siemens | SCALANCE S615 LAN-Router | All versions < V4.3: affected |
| Siemens | SCALANCE W-700 IEEE 802.11n family | All versions <= V6.0.1: affected |
| Siemens | SCALANCE X200-4P IRT | All Versions < V5.3: affected |
| Siemens | SCALANCE X201-3P IRT | All Versions < V5.3: affected |
| Siemens | SCALANCE X201-3P IRT PRO | All Versions < V5.3: affected |
| Siemens | SCALANCE X202-2IRT | All Versions < V5.3: affected |
| Siemens | SCALANCE X202-2P IRT | All Versions < V5.3: affected |
| Siemens | SCALANCE X202-2P IRT PRO | All Versions < V5.3: affected |
| Siemens | SCALANCE X204-2 | All versions < V5.2.5: affected |
| Siemens | SCALANCE X204-2FM | All versions < V5.2.5: affected |
| Siemens | SCALANCE X204-2LD | All versions < V5.2.5: affected |
| Siemens | SCALANCE X204-2LD TS | All versions < V5.2.5: affected |
| Siemens | SCALANCE X204-2TS | All versions < V5.2.5: affected |
| Siemens | SCALANCE X204IRT | All Versions < V5.3: affected |
| Siemens | SCALANCE X204IRT PRO | All Versions < V5.3: affected |
| Siemens | SCALANCE X206-1 | All versions < V5.2.5: affected |
| Siemens | SCALANCE X206-1LD | All versions < V5.2.5: affected |
| Siemens | SCALANCE X208 | All versions < V5.2.5: affected |
| Siemens | SCALANCE X208PRO | All versions < V5.2.5: affected |
| Siemens | SCALANCE X212-2 | All versions < V5.2.5: affected |
| Siemens | SCALANCE X212-2LD | All versions < V5.2.5: affected |
| Siemens | SCALANCE X216 | All versions < V5.2.5: affected |
| Siemens | SCALANCE X224 | All versions < V5.2.5: affected |
| Siemens | SCALANCE X302-7 EEC (230V, coated) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X302-7 EEC (230V) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X302-7 EEC (24V, coated) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X302-7 EEC (24V) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X302-7 EEC (2x 230V, coated) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X302-7 EEC (2x 230V) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X302-7 EEC (2x 24V, coated) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X302-7 EEC (2x 24V) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X304-2FE | All versions < V4.1.4: affected |
| Siemens | SCALANCE X306-1LD FE | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-2 EEC (230V, coated) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-2 EEC (230V) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-2 EEC (24V, coated) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-2 EEC (24V) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-2 EEC (2x 230V, coated) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-2 EEC (2x 230V) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-2 EEC (2x 24V, coated) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-2 EEC (2x 24V) | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-3 | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-3 | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-3LD | All versions < V4.1.4: affected |
| Siemens | SCALANCE X307-3LD | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2 | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2 | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2LD | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2LD | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2LH | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2LH | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2LH+ | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2LH+ | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2M | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2M | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2M PoE | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2M PoE | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2M TS | All versions < V4.1.4: affected |
| Siemens | SCALANCE X308-2M TS | All versions < V4.1.4: affected |
| Siemens | SCALANCE X310 | All versions < V4.1.4: affected |
| Siemens | SCALANCE X310 | All versions < V4.1.4: affected |
| Siemens | SCALANCE X310FE | All versions < V4.1.4: affected |
| Siemens | SCALANCE X310FE | All versions < V4.1.4: affected |
| Siemens | SCALANCE X320-1 FE | All versions < V4.1.4: affected |
| Siemens | SCALANCE X320-1-2LD FE | All versions < V4.1.4: affected |
| Siemens | SCALANCE X408-2 | All versions < V4.1.4: affected |
| Siemens | SCALANCE XB-200 family | All Versions < V3.0: affected |
| Siemens | SCALANCE XC-200 | All Versions < V3.0: affected |
| Siemens | SCALANCE XF-200BA | All Versions < V3.0: affected |
| Siemens | SCALANCE XF201-3P IRT | All Versions < V5.3: affected |
| Siemens | SCALANCE XF202-2P IRT | All Versions < V5.3: affected |
| Siemens | SCALANCE XF204 | All versions < V5.2.5: affected |
| Siemens | SCALANCE XF204-2 | All versions < V5.2.5: affected |
| Siemens | SCALANCE XF204-2BA IRT | All Versions < V5.3: affected |
| Siemens | SCALANCE XF204IRT | All Versions < V5.3: affected |
| Siemens | SCALANCE XF206-1 | All versions < V5.2.5: affected |
| Siemens | SCALANCE XF208 | All versions < V5.2.5: affected |
| Siemens | SCALANCE XM-400 family | All Versions < V6.0: affected |
| Siemens | SCALANCE XP-200 | All Versions < V3.0: affected |
| Siemens | SCALANCE XR-300WG family | All Versions < V3.0: affected |
| Siemens | SCALANCE XR-500 family | All Versions < V6.0: affected |
| Siemens | SCALANCE XR324-12M (230V, ports on front) | All versions < V4.1.4: affected |
| Siemens | SCALANCE XR324-12M (230V, ports on front) | All versions < V4.1.4: affected |
The source lists more products than DeSpy shows; see the source record.
Products named in NVD's CPE match criteria (50)
cpe:2.3:a:siemens:dk_standard_ethernet_controller:*:*:*:*:*:*:*:*cpe:2.3:a:siemens:profinet_driver:*:*:*:*:*:*:*:*cpe:2.3:a:siemens:simatic_ipc_support:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xf-200_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_x-400_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_343-1_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_343-1_advanced_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_343-1_erpc_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_cp_443-1_opc_ua_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200al_im_157-1_pn_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200m_im153-4_pn_io_hf_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200m_im153-4_pn_io_st_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200mp_im155-5_pn_hf_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200mp_im155-5_pn_st_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200s_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_basic_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_hf_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_st_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200ecopn_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_et200pro_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:im_154-3_pn_hf_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:im_154-4_pn_hf_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_mv440_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_mv420_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_pn\/pn_coupler_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_rf180c_firmware:*:*:*:*:*:*:*:*cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*
DeSpy has not checked any unit, hardware revision or firmware. A product missing here is not a statement that it is unaffected.
Scores, as their sources published them
- CVSS 3.1: 7.5 HIGH — as published by Siemens AG (Secondary)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 3.1: 7.5 HIGH — as published by NIST (Secondary)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 2.0: 7.8 HIGH — as published by NIST (Primary)
AV:N/AC:L/Au:N/C:N/I:N/A:C - SSVC — CISA's assessment (SSVC 2.0.3, CISA Coordinator): Exploitation: none · Automatable: yes · Technical impact: partial
DeSpy does not score records. These are the sources' own values.
Weaknesses
Sources
References the source lists
- https://cert-portal.siemens.com/productcert/html/ssa-780073.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-780073.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf
Source dates: published 2020-02-11, last changed 2026-06-17. DeSpy's copy of this version is dated 2026-09-28.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.