← Security Alerts

CVE-2021-25667

Siemens · published 2021-03-15

Source record Collected from the National Vulnerability Database (NVD)

Description

Description by Siemens AG via the CVE Program.

A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.

Status at the source

Affected products, as the source lists them

VendorProductVersions
SiemensRUGGEDCOM RM1224All versions >= V4.3 and < V6.4: affected
SiemensSCALANCE M-800All versions >= V4.3 and < V6.4: affected
SiemensSCALANCE S615All versions >= V4.3 and < V6.4: affected
SiemensSCALANCE SC-600 FamilyAll versions >= V2.0 and < V2.1.3: affected
SiemensSCALANCE XB-200All versions < V4.1: affected
SiemensSCALANCE XC-200All versions < V4.1: affected
SiemensSCALANCE XF-200BAAll versions < V4.1: affected
SiemensSCALANCE XM400All versions < V6.2: affected
SiemensSCALANCE XP-200All versions < V4.1: affected
SiemensSCALANCE XR-300WGAll versions < V4.1: affected
SiemensSCALANCE XR500All versions < V6.2: affected
Products named in NVD's CPE match criteria (15)
  • cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x300wg_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*

DeSpy has not checked any unit, hardware revision or firmware. A product missing here is not a statement that it is unaffected.

Scores, as their sources published them

DeSpy does not score records. These are the sources' own values.

Weaknesses

CWE-121, CWE-787

Sources

References the source lists

Source dates: published 2021-03-15, last changed 2026-06-17. DeSpy's copy of this version is dated 2026-09-28.

This product uses the NVD API but is not endorsed or certified by the NVD.

CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.

CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.

CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.

Scope, sources and licences →