← Security Alerts

CVE-2023-32736

Siemens · published 2024-11-12

Source record Collected from the National Vulnerability Database (NVD)

Description

Description by Siemens AG via the CVE Program.

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

Status at the source

Affected products, as the source lists them

VendorProductVersions
SiemensSIMATIC S7-PLCSIM V160 – before *: affected
SiemensSIMATIC S7-PLCSIM V170 – before *: affected
SiemensSIMATIC STEP 7 Safety V160 – before *: affected
SiemensSIMATIC STEP 7 Safety V170 – before V17 Update 8: affected
SiemensSIMATIC STEP 7 Safety V180 – before V18 Update 5: affected
SiemensSIMATIC STEP 7 V160 – before *: affected
SiemensSIMATIC STEP 7 V170 – before V17 Update 8: affected
SiemensSIMATIC STEP 7 V180 – before V18 Update 5: affected
SiemensSIMATIC WinCC Unified V160 – before *: affected
SiemensSIMATIC WinCC Unified V170 – before V17 Update 8: affected
SiemensSIMATIC WinCC Unified V180 – before V18 SP5: affected
SiemensSIMATIC WinCC V160 – before *: affected
SiemensSIMATIC WinCC V170 – before V17 Update 8: affected
SiemensSIMATIC WinCC V180 – before V18 SP5: affected
SiemensSIMOCODE ES V160 – before *: affected
SiemensSIMOCODE ES V170 – before V17 Update 8: affected
SiemensSIMOCODE ES V180 – before *: affected
SiemensSIMOTION SCOUT TIA V5.4 SP10 – before *: affected
SiemensSIMOTION SCOUT TIA V5.4 SP30 – before *: affected
SiemensSIMOTION SCOUT TIA V5.5 SP10 – before *: affected
SiemensSINAMICS Startdrive V160 – before *: affected
SiemensSINAMICS Startdrive V170 – before *: affected
SiemensSINAMICS Startdrive V180 – before *: affected
SiemensSIRIUS Safety ES V17 (TIA Portal)0 – before V17 Update 8: affected
SiemensSIRIUS Safety ES V18 (TIA Portal)0 – before *: affected
SiemensSIRIUS Soft Starter ES V17 (TIA Portal)0 – before V17 Update 8: affected
SiemensSIRIUS Soft Starter ES V18 (TIA Portal)0 – before *: affected
SiemensTIA Portal Cloud V160 – before *: affected
SiemensTIA Portal Cloud V170 – before V4.6.0.1: affected
SiemensTIA Portal Cloud V180 – before V4.6.1.0: affected

Added by CISA-ADP (Authorized Data Publisher)

VendorProductVersions
siemenssimatic_step_716 – before 17: affected
17 – before 17_update8: affected
18 – before 18_update5: affected
siemenssimatic_step_716 – before 17: affected
17 – before 17_update8: affected
18 – before 18_update5: affected
siemenssimatic_s7-plcsim16 – before 17: affected
17 – before *: affected
siemenssimatic_wincc16 – before 17: affected
17 – before 17_update8: affected
18 – before 18_update5: affected
siemenssimatic_wincc_unified16 – before 17: affected
17 – before 17_update8: affected
18 – before 18_update5: affected
siemenssimocode_es16 – before 17: affected
17 – before 17_update8: affected
18 – before *: affected
siemenssimotion_scout_tiav5.4sp1 – before *: affected
v5.4sp3 – before *: affected
v5.5sp1 – before *: affected
siemenssinamics_startdrive16 – before 17: affected
17 – before 18: affected
18 – before *: affected
siemenssirius_safety_es0 – before 17_update8: affected
18 – before *: affected
siemenstia_portal_cloud16 – before *: affected
17 – before *: affected
18 – before *: affected

DeSpy has not checked any unit, hardware revision or firmware. A product missing here is not a statement that it is unaffected.

Scores, as their sources published them

DeSpy does not score records. These are the sources' own values.

Weaknesses

CWE-502

Sources

References the source lists

Source dates: published 2024-11-12, last changed 2026-06-17. DeSpy's copy of this version is dated 2026-09-28.

This product uses the NVD API but is not endorsed or certified by the NVD.

CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.

CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.

CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.

Scope, sources and licences →