A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. The web server of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause total loss of availability of the web server, which might recover after the attack is over.
Status at the source
- NVD status: Modified
Affected products, as the source lists them
| Vendor | Product | Versions |
|---|---|---|
| Siemens | RUGGEDCOM i800 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM i800NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM i801 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM i801NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM i802 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM i802NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM i803 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM i803NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM M2100 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM M2100F | 0 – before *: affected |
| Siemens | RUGGEDCOM M2100NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM M2200 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM M2200F | 0 – before *: affected |
| Siemens | RUGGEDCOM M2200NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM M969 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM M969F | 0 – before *: affected |
| Siemens | RUGGEDCOM M969NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RMC30 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RMC30NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RMC8388 V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RMC8388 V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RMC8388NC V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RMC8388NC V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RP110 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RP110NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS1600 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS1600F | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS1600FNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS1600NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS1600T | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS1600TNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS400 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS400F | 0 – before *: affected |
| Siemens | RUGGEDCOM RS400NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS401 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS401NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS416 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS416F | 0 – before *: affected |
| Siemens | RUGGEDCOM RS416NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS416NCv2 V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS416NCv2 V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RS416P | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS416PF | 0 – before *: affected |
| Siemens | RUGGEDCOM RS416PNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS416PNCv2 V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS416PNCv2 V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RS416Pv2 V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS416Pv2 V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RS416v2 V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS416v2 V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RS8000 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS8000A | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS8000ANC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS8000H | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS8000HNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS8000NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS8000T | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS8000TNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900 (32M) V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900 (32M) V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RS900F | 0 – before *: affected |
| Siemens | RUGGEDCOM RS900G | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900G (32M) V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900G (32M) V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RS900GF | 0 – before *: affected |
| Siemens | RUGGEDCOM RS900GNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900GNC(32M) V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900GNC(32M) V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RS900GP | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900GPF | 0 – before *: affected |
| Siemens | RUGGEDCOM RS900GPNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900L | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900LNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900M-GETS-C01 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900M-GETS-XX | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900M-STND-C01 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900M-STND-XX | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900MNC-GETS-C01 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900MNC-GETS-XX | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900MNC-STND-XX | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900MNC-STND-XX-C01 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900NC(32M) V4.X | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS900NC(32M) V5.X | 0 – before V5.8.0: affected |
| Siemens | RUGGEDCOM RS900W | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS910 | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS910L | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS910LNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS910NC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS910W | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS920L | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS920LNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS920W | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS930L | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS930LNC | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS930W | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS940G | 0 – before V4.3.8: affected |
| Siemens | RUGGEDCOM RS940GF | 0 – before *: affected |
| Siemens | RUGGEDCOM RS940GNC | 0 – before V4.3.8: affected |
The source lists more products than DeSpy shows; see the source record.
Products named in NVD's CPE match criteria (1)
cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:*
DeSpy has not checked any unit, hardware revision or firmware. A product missing here is not a statement that it is unaffected.
Scores, as their sources published them
- CVSS 3.1: 7.5 HIGH — as published by Siemens AG (Secondary)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 3.1: 7.5 HIGH — as published by NIST (Primary)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - SSVC — CISA's assessment (SSVC 2.0.3, CISA Coordinator): Exploitation: none · Automatable: yes · Technical impact: partial
DeSpy does not score records. These are the sources' own values.
Weaknesses
Sources
References the source lists
- https://cert-portal.siemens.com/productcert/html/ssa-770902.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-770902.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-770902.pdf
Source dates: published 2023-08-08, last changed 2026-06-17. DeSpy's copy of this version is dated 2026-09-28.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.
CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.