Siemens · published 2024-12-10

Source record Collected from the National Vulnerability Database (NVD)

Description

Description by Siemens AG via the CVE Program.

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

Status at the source

Affected products, as the source lists them

VendorProductVersions
SiemensSIMATIC S7-PLCSIM V160 – before *: affected
SiemensSIMATIC S7-PLCSIM V170 – before *: affected
SiemensSIMATIC STEP 7 Safety V160 – before *: affected
SiemensSIMATIC STEP 7 Safety V170 – before V17 Update 9: affected
SiemensSIMATIC STEP 7 Safety V180 – before *: affected
SiemensSIMATIC STEP 7 Safety V190 – before V19 Update 4: affected
SiemensSIMATIC STEP 7 V160 – before *: affected
SiemensSIMATIC STEP 7 V170 – before V17 Update 9: affected
SiemensSIMATIC STEP 7 V180 – before *: affected
SiemensSIMATIC STEP 7 V190 – before V19 Update 4: affected
SiemensSIMATIC WinCC Unified V160 – before *: affected
SiemensSIMATIC WinCC Unified V170 – before V17 Update 9: affected
SiemensSIMATIC WinCC Unified V180 – before *: affected
SiemensSIMATIC WinCC Unified V190 – before V19 Update 4: affected
SiemensSIMATIC WinCC V160 – before *: affected
SiemensSIMATIC WinCC V170 – before V17 Update 9: affected
SiemensSIMATIC WinCC V180 – before *: affected
SiemensSIMATIC WinCC V190 – before V19 Update 4: affected
SiemensSIMOCODE ES V160 – before *: affected
SiemensSIMOCODE ES V170 – before *: affected
SiemensSIMOCODE ES V180 – before *: affected
SiemensSIMOCODE ES V190 – before *: affected
SiemensSIMOTION SCOUT TIA V5.40 – before *: affected
SiemensSIMOTION SCOUT TIA V5.50 – before *: affected
SiemensSIMOTION SCOUT TIA V5.60 – before V5.6 SP1 HF7: affected
SiemensSINAMICS Startdrive V160 – before *: affected
SiemensSINAMICS Startdrive V170 – before *: affected
SiemensSINAMICS Startdrive V180 – before *: affected
SiemensSINAMICS Startdrive V190 – before *: affected
SiemensSIRIUS Safety ES V17 (TIA Portal)0 – before *: affected
SiemensSIRIUS Safety ES V18 (TIA Portal)0 – before *: affected
SiemensSIRIUS Safety ES V19 (TIA Portal)0 – before *: affected
SiemensSIRIUS Soft Starter ES V17 (TIA Portal)0 – before *: affected
SiemensSIRIUS Soft Starter ES V18 (TIA Portal)0 – before *: affected
SiemensSIRIUS Soft Starter ES V19 (TIA Portal)0 – before *: affected
SiemensTIA Portal Cloud V160 – before *: affected
SiemensTIA Portal Cloud V170 – before *: affected
SiemensTIA Portal Cloud V180 – before *: affected
SiemensTIA Portal Cloud V190 – before V5.2.1.1: affected

DeSpy has not checked any unit, hardware revision or firmware. A product missing here is not a statement that it is unaffected.

Scores, as their sources published them

DeSpy does not score records. These are the sources' own values.

Weaknesses

CWE-502

Sources

References the source lists

Source dates: published 2024-12-10, last changed 2026-06-17. DeSpy's copy of this version is dated 2026-09-28.

This product uses the NVD API but is not endorsed or certified by the NVD.

CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.

CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.

CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.

Scope, sources and licences →