← Security Alerts

CVE-2024-54015

Siemens · published 2025-02-11

Source record Collected from the National Vulnerability Database (NVD)

Description

Description by Siemens AG via the CVE Program.

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials.

Status at the source

Affected products, as the source lists them

VendorProductVersions
SiemensSIPROTEC 5 6MD84 (CP300)0 – before V9.90: affected
SiemensSIPROTEC 5 6MD85 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 6MD86 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 6MD89 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 6MD89 (CP300) V9.6x0 – before V9.68: affected
SiemensSIPROTEC 5 6MU85 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7KE85 (CP300)V8.80 – before V10.0: affected
SiemensSIPROTEC 5 7SA82 (CP150)0 – before V9.90: affected
SiemensSIPROTEC 5 7SA86 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SA87 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SD82 (CP150)0 – before V9.90: affected
SiemensSIPROTEC 5 7SD86 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SD87 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SJ81 (CP150)0 – before V9.90: affected
SiemensSIPROTEC 5 7SJ82 (CP150)0 – before V9.90: affected
SiemensSIPROTEC 5 7SJ85 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SJ86 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SK82 (CP150)0 – before V9.90: affected
SiemensSIPROTEC 5 7SK85 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SL82 (CP150)0 – before V9.90: affected
SiemensSIPROTEC 5 7SL86 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SL87 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SS85 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7ST85 (CP300)V8.80 – before V10.0: affected
SiemensSIPROTEC 5 7ST85 (CP300) V9.6x0 – before V9.68: affected
SiemensSIPROTEC 5 7ST86 (CP300)0 – before V10.0: affected
SiemensSIPROTEC 5 7ST86 (CP300) V9.8x0 – before V9.83: affected
SiemensSIPROTEC 5 7SX82 (CP150)0 – before V9.90: affected
SiemensSIPROTEC 5 7SX85 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7SY82 (CP150)0 – before V9.90: affected
SiemensSIPROTEC 5 7UM85 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7UT82 (CP150)0 – before V9.90: affected
SiemensSIPROTEC 5 7UT85 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7UT86 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7UT87 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7VE85 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7VK87 (CP300)V8.80 – before V9.90: affected
SiemensSIPROTEC 5 7VU85 (CP300)0 – before V9.90: affected
SiemensSIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2)0 – before V9.90: affected
SiemensSIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.60 – before V9.68: affected
SiemensSIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.80 – before V9.83: affected
SiemensSIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2)0 – before V9.90: affected
SiemensSIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.60 – before V9.68: affected
SiemensSIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.80 – before V9.83: affected
SiemensSIPROTEC 5 Communication Module ETH-BD-2FOV8.80 – before V9.90: affected
SiemensSIPROTEC 5 Communication Module ETH-BD-2FO V9.60 – before V9.68: affected
SiemensSIPROTEC 5 Communication Module ETH-BD-2FO V9.80 – before V9.83: affected
SiemensSIPROTEC 5 Compact 7SX800 (CP050)V9.50 – before V9.90: affected

DeSpy has not checked any unit, hardware revision or firmware. A product missing here is not a statement that it is unaffected.

Scores, as their sources published them

DeSpy does not score records. These are the sources' own values.

Weaknesses

CWE-1392

Sources

References the source lists

Source dates: published 2025-02-11, last changed 2026-06-17. DeSpy's copy of this version is dated 2026-09-28.

This product uses the NVD API but is not endorsed or certified by the NVD.

CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.

CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.

CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.

Scope, sources and licences →