CVE-2026-58114
Siemens · published 2026-11-10
Source record Collected from the National Vulnerability Database (NVD)
Description
Description by Siemens AG via the CVE Program.
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Runtime Professional V20 (All versions), SIMATIC WinCC Runtime Professional V21 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.
Status at the source
- NVD status: Awaiting Analysis — NVD has not analysed this CVE.
Affected products, as the source lists them
| Vendor | Product | Versions |
|---|---|---|
| Siemens | SIMATIC BATCH V9.1 | 0 – before *: affected |
| Siemens | SIMATIC Information Server 2020 | 0 – before *: affected |
| Siemens | SIMATIC Information Server 2022 | 0 – before *: affected |
| Siemens | SIMATIC PCS 7 V9.1 | 0 – before *: affected |
| Siemens | SIMATIC Process Historian 2020 | 0 – before *: affected |
| Siemens | SIMATIC Process Historian 2022 | 0 – before *: affected |
| Siemens | SIMATIC WinCC Runtime Professional V17 | 0 – before *: affected |
| Siemens | SIMATIC WinCC Runtime Professional V18 | 0 – before *: affected |
| Siemens | SIMATIC WinCC Runtime Professional V19 | 0 – before *: affected |
| Siemens | SIMATIC WinCC Runtime Professional V20 | 0 – before *: affected |
| Siemens | SIMATIC WinCC Runtime Professional V21 | 0 – before *: affected |
| Siemens | SIMATIC WinCC V7.5 | 0 – before *: affected |
| Siemens | SIMATIC WinCC V8.0 | 0 – before *: affected |
| Siemens | SIMATIC WinCC V8.1 | 0 – before *: affected |
DeSpy has not checked any unit, hardware revision or firmware. A product missing here is not a statement that it is unaffected.
Scores, as their sources published them
- CVSS 4.0: 7.7 HIGH — as published by Siemens AG (Secondary)
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1: 7.5 HIGH — as published by Siemens AG (Secondary)
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H - SSVC — CISA's assessment (SSVC 2.0.3, CISA Coordinator): Exploitation: none · Automatable: no · Technical impact: total
DeSpy does not score records. These are the sources' own values.
Weaknesses
Sources
References the source lists
Source dates: published 2026-11-10, last changed 2026-11-12. DeSpy's copy of this version is dated 2026-11-12.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.
CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.