ICSA-22-104-09: Siemens SCALANCE X-300 Switches
CISA advisory · released 2022-04-12
Source record Collected from CISA's CSAF advisory feed
- Distribution label in the document: TLP:WHITE
- Revision 2, 2025-05-06 (final)
CISA's summary
Summary: Several SCALANCE X-300 switches contain multiple vulnerabilities. An unauthenticated attacker could reboot, cause denial of service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
Products, as the advisory lists them
| Vendor | Product | Version |
|---|---|---|
| Siemens | SCALANCE X302-7 EEC (2x 24V) | <V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (2x 24V, coated) | <V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (2x 230V) | <V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (2x 230V, coated) | <V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (24V) | <V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (24V, coated) | <V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (230V) | <V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (230V, coated) | <V4.1.4 |
| Siemens | SCALANCE X304-2FE | <V4.1.4 |
| Siemens | SCALANCE X306-1LD FE | <V4.1.4 |
| Siemens | SCALANCE X307-2 EEC (2x 24V) | <V4.1.4 |
| Siemens | SCALANCE X307-2 EEC (2x 24V, coated) | <V4.1.4 |
| Siemens | SCALANCE X307-2 EEC (2x 230V) | <V4.1.4 |
| Siemens | SCALANCE X307-2 EEC (2x 230V, coated) | <V4.1.4 |
| Siemens | SCALANCE X307-2 EEC (24V) | <V4.1.4 |
| Siemens | SCALANCE X307-2 EEC (24V, coated) | <V4.1.4 |
| Siemens | SCALANCE X307-2 EEC (230V) | <V4.1.4 |
| Siemens | SCALANCE X307-2 EEC (230V, coated) | <V4.1.4 |
| Siemens | SCALANCE X307-3 | <V4.1.4 |
| Siemens | SCALANCE X307-3LD | <V4.1.4 |
| Siemens | SCALANCE X308-2 | <V4.1.4 |
| Siemens | SCALANCE X308-2LD | <V4.1.4 |
| Siemens | SCALANCE X308-2LH | <V4.1.4 |
| Siemens | SCALANCE X308-2LH+ | <V4.1.4 |
| Siemens | SCALANCE X308-2M | <V4.1.4 |
| Siemens | SCALANCE X308-2M PoE | <V4.1.4 |
| Siemens | SCALANCE X308-2M TS | <V4.1.4 |
| Siemens | SCALANCE X310 | <V4.1.4 |
| Siemens | SCALANCE X310FE | <V4.1.4 |
| Siemens | SCALANCE X320-1 FE | <V4.1.4 |
| Siemens | SCALANCE X320-1-2LD FE | <V4.1.4 |
| Siemens | SCALANCE X408-2 | <V4.1.4 |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on front) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on rear) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on front) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on rear) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M PoE (24V, ports on front) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M PoE (24V, ports on rear) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M PoE (230V, ports on front) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M PoE (230V, ports on rear) | <V4.1.4 |
| Siemens | SCALANCE XR324-4M PoE TS (24V, ports on front) | <V4.1.4 |
| Siemens | SCALANCE XR324-12M (24V, ports on front) | <V4.1.4 |
| Siemens | SCALANCE XR324-12M (24V, ports on rear) | <V4.1.4 |
| Siemens | SCALANCE XR324-12M (230V, ports on front) | <V4.1.4 |
| Siemens | SCALANCE XR324-12M (230V, ports on rear) | <V4.1.4 |
| Siemens | SCALANCE XR324-12M TS (24V) | <V4.1.4 |
| Siemens | SIPLUS NET SCALANCE X308-2 | <V4.1.4 |
DeSpy has not checked any unit, hardware revision or firmware.
Vulnerabilities in this advisory
- CVE-2022-25751 — CVE-2022-25751 · CWE-20
Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices.
- CVE-2022-25752 — CVE-2022-25752 · CWE-330
The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
- CVE-2022-25753 — CVE-2022-25753 · CWE-121
The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.
- CVE-2022-25754 — CVE-2022-25754 · CWE-352
The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.
- CVE-2022-25755 — CVE-2022-25755 · CWE-284
The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.
- CVE-2022-25756 — CVE-2022-25756 · CWE-80
The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.
- CVE-2022-26334 — CVE-2022-26334 · CWE-120
Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.
- CVE-2022-26335 — CVE-2022-26335 · CWE-120
Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.
- CVE-2022-26380 — CVE-2022-26380 · CWE-125
Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device.
Acknowledgments, as the advisory lists them
- Siemens ProductCERT: reporting this vulnerability to CISA.
- Michael Messner, Abian Blome, Siemens Energy: coordinated disclosure of CVE-2022-25751 - CVE-2022-25756
The advisory's legal notice
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Sources
DeSpy's copy of this version is dated 2026-09-28.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.
CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.