ICSA-22-167-10: Siemens SCALANCE XM-400 and XR-500
CISA advisory · released 2022-06-14
Source record Collected from CISA's CSAF advisory feed
- Distribution label in the document: TLP:WHITE
- Revision 1, 2022-06-14 (final)
CISA's summary
Summary: SCALANCE XM-400 and XR-500 devices contain a vulnerability in the OSPF protocol implementation that could allow an unauthenticated remote attacker to cause interruptions in the network. Siemens has released updates for the affected products and recommends to update to the latest versions.
Products, as the advisory lists them
| Vendor | Product | Version |
|---|---|---|
| Siemens | SCALANCE XM408-4C | <V6.5 |
| Siemens | SCALANCE XM408-4C (L3 int.) | <V6.5 |
| Siemens | SCALANCE XM408-8C | <V6.5 |
| Siemens | SCALANCE XM408-8C (L3 int.) | <V6.5 |
| Siemens | SCALANCE XM416-4C | <V6.5 |
| Siemens | SCALANCE XM416-4C (L3 int.) | <V6.5 |
| Siemens | SCALANCE XR524-8C, 1x230V | <V6.5 |
| Siemens | SCALANCE XR524-8C, 1x230V (L3 int.) | <V6.5 |
| Siemens | SCALANCE XR524-8C, 2x230V | <V6.5 |
| Siemens | SCALANCE XR524-8C, 2x230V (L3 int.) | <V6.5 |
| Siemens | SCALANCE XR524-8C, 24V | <V6.5 |
| Siemens | SCALANCE XR524-8C, 24V (L3 int.) | <V6.5 |
| Siemens | SCALANCE XR526-8C, 1x230V | <V6.5 |
| Siemens | SCALANCE XR526-8C, 1x230V (L3 int.) | <V6.5 |
| Siemens | SCALANCE XR526-8C, 2x230V | <V6.5 |
| Siemens | SCALANCE XR526-8C, 2x230V (L3 int.) | <V6.5 |
| Siemens | SCALANCE XR526-8C, 24V | <V6.5 |
| Siemens | SCALANCE XR526-8C, 24V (L3 int.) | <V6.5 |
| Siemens | SCALANCE XR528-6M | <V6.5 |
| Siemens | SCALANCE XR528-6M (2HR2) | <V6.5 |
| Siemens | SCALANCE XR528-6M (2HR2, L3 int.) | <V6.5 |
| Siemens | SCALANCE XR528-6M (L3 int.) | <V6.5 |
| Siemens | SCALANCE XR552-12M | <V6.5 |
| Siemens | SCALANCE XR552-12M (2HR2) | <V6.5 |
| Siemens | SCALANCE XR552-12M (2HR2, L3 int.) | <V6.5 |
DeSpy has not checked any unit, hardware revision or firmware.
Vulnerabilities in this advisory
- CVE-2021-37182 — CVE-2021-37182 · CWE-354
The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.
Acknowledgments, as the advisory lists them
- Siemens ProductCERT: reporting this vulnerability to CISA.
The advisory's legal notice
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Sources
DeSpy's copy of this version is dated 2026-09-28.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.