ICSA-24-165-12: Siemens SCALANCE W700
CISA advisory · released 2024-06-11
Source record Collected from CISA's CSAF advisory feed
- Distribution label in the document: TLP:WHITE
- Revision 3, 2025-01-14 (final)
CISA's summary
Summary: SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11ax family and recommends to update to the latest version. Siemens recommends countermeasures for vulnerabilities where fixes are not, or not yet available.
Products, as the advisory lists them
| Vendor | Product | Version |
|---|---|---|
| Siemens | SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) | vers:all/* |
| Siemens | SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) | vers:all/* |
| Siemens | SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) | vers:all/* |
| Siemens | SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) | vers:all/* |
| Siemens | SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) | vers:all/* |
| Siemens | SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) | vers:all/* |
| Siemens | SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) | vers:all/* |
| Siemens | SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) | vers:all/* |
| Siemens | SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) | vers:all/* |
| Siemens | SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) | vers:all/* |
| Siemens | SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) | vers:all/* |
| Siemens | SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) | vers:all/* |
| Siemens | SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) | vers:all/<V3.0.0 |
| Siemens | SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) | vers:all/* |
DeSpy has not checked any unit, hardware revision or firmware.
Vulnerabilities in this advisory
- CVE-2023-44317 — CVE-2023-44317 · CWE-349
Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device.
- CVE-2023-44318 — CVE-2023-44318 · CWE-321
Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file.
- CVE-2023-44319 — CVE-2023-44319 · CWE-328
Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device.
- CVE-2023-44374 — CVE-2023-44374 · CWE-567
Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user, which could allow to escalate privileges.
Acknowledgments, as the advisory lists them
- Siemens ProductCERT: reporting these vulnerabilities to CISA.
The advisory's legal notice
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Sources
DeSpy's copy of this version is dated 2026-09-28.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.
CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.