CISA's summary
Summary: SENTRON 7KT PAC1260 Data Manager is affected by multiple vulnerabilities as listed below. Software fixes can no longer be provided for The SENTRON 7KT PAC1260 Data Manager. This advisory documents the known open vulnerabilities. To fix the vulnerabilities, Siemens recommends to replace the device by the new SENTRON 7KT PAC1261 Data Manager and update it to the latest available firmware version.
Products, as the advisory lists them
| Vendor | Product | Version |
|---|---|---|
| Siemens | SENTRON 7KT PAC1260 Data Manager | vers:all/* |
DeSpy has not checked any unit, hardware revision or firmware.
Vulnerabilities in this advisory
- CVE-2024-41788 — CVE-2024-41788 · CWE-78
The web interface of affected devices does not sanitize the input parameters in specific GET requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
- CVE-2024-41789 — CVE-2024-41789 · CWE-78
The web interface of affected devices does not sanitize the language parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
- CVE-2024-41790 — CVE-2024-41790 · CWE-78
The web interface of affected devices does not sanitize the region parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
- CVE-2024-41791 — CVE-2024-41791 · CWE-306
The web interface of affected devices does not authenticate report creation requests. This could allow an unauthenticated remote attacker to read or clear the log files on the device, reset the device or set the date and time.
- CVE-2024-41792 — CVE-2024-41792 · CWE-22
The web interface of affected devices contains a path traversal vulnerability. This could allow an unauthenticated attacker it to access arbitrary files on the device with root privileges.
- CVE-2024-41793 — CVE-2024-41793 · CWE-306
The web interface of affected devices provides an endpoint that allows to enable the ssh service without authentication. This could allow an unauthenticated remote attacker to enable remote access to the device via ssh.
- CVE-2024-41794 — CVE-2024-41794 · CWE-798
Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could allow unauthenticated remote attackers to gain full access to a device, if they are in possession of these credentials and if the ssh service is enabled (e.g., by exploitation of CVE-2024-41793).
- CVE-2024-41795 — CVE-2024-41795 · CWE-352
The web interface of affected devices is vulnerable to Cross-Site Request Forgery (CSRF) attacks. This could allow an unauthenticated attacker to change arbitrary device settings by tricking a legitimate device administrator to click on a malicious link.
- CVE-2024-41796 — CVE-2024-41796 · CWE-620
The web interface of affected devices allows to change the login password without knowing the current password. In combination with a prepared CSRF attack (CVE-2024-41795) an unauthenticated attacker could be able to set the password to an attacker-controlled value.
Acknowledgments, as the advisory lists them
- Michael Messner, Benedikt Kühne, Siemens Energy: reporting these vulnerabilities to Siemens.
The advisory's legal notice
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Sources
DeSpy's copy of this version is dated 2026-09-28.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.
CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.