ICSA-26-174-03: Siemens Products using OpenSSL
CISA advisory · released 2026-06-09
Source record Collected from CISA's CSAF advisory feed
- Distribution label in the document: TLP:WHITE
- Revision 6, 2026-09-15 (final)
CISA's summary
Summary: OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Products, as the advisory lists them
| Vendor | Product | Version |
|---|---|---|
| Siemens | AI Lightweight Inference Server | vers:all/* |
| Siemens | Connector for Azure | vers:intdot/<1.8.0 |
| Siemens | Databus | vers:intdot/<3.3.2 |
| Siemens | HiMed Cockpit | vers:all/* |
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) | vers:all/* |
| Siemens | RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) | vers:all/* |
| Siemens | RUGGEDCOM ROX MX5000 | vers:all/* |
| Siemens | RUGGEDCOM ROX MX5000RE | vers:all/* |
| Siemens | RUGGEDCOM ROX RX1400 | vers:all/* |
| Siemens | RUGGEDCOM ROX RX1500 | vers:all/* |
| Siemens | RUGGEDCOM ROX RX1501 | vers:all/* |
| Siemens | RUGGEDCOM ROX RX1510 | vers:all/* |
| Siemens | RUGGEDCOM ROX RX1511 | vers:all/* |
| Siemens | RUGGEDCOM ROX RX1512 | vers:all/* |
| Siemens | RUGGEDCOM ROX RX1524 | vers:all/* |
| Siemens | RUGGEDCOM ROX RX1536 | vers:all/* |
| Siemens | RUGGEDCOM ROX RX5000 | vers:all/* |
| Siemens | SCALANCE LPE9403 (6GK5998-3GS00-2AC2) | vers:all/* |
| Siemens | SCALANCE LPE9413 (6GK5998-3GS01-2AC2) | vers:all/* |
| Siemens | SCALANCE LPE9433 (6GK5998-3GS11-2AC2) | vers:all/* |
| Siemens | SCALANCE M804PB (6GK5804-0AP00-2AA2) | vers:all/* |
| Siemens | SCALANCE M812-1 ADSL-Router family | vers:all/* |
| Siemens | SCALANCE M816-1 ADSL-Router family | vers:all/* |
| Siemens | SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) | vers:all/* |
| Siemens | SCALANCE M874-2 (6GK5874-2AA00-2AA2) | vers:all/* |
| Siemens | SCALANCE M874-3 (6GK5874-3AA00-2AA2) | vers:all/* |
| Siemens | SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) | vers:all/* |
| Siemens | SCALANCE M876-3 (6GK5876-3AA02-2BA2) | vers:all/* |
| Siemens | SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) | vers:all/* |
| Siemens | SCALANCE M876-4 (6GK5876-4AA10-2BA2) | vers:all/* |
| Siemens | SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) | vers:all/* |
| Siemens | SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) | vers:all/* |
| Siemens | SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1) | vers:all/* |
| Siemens | SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1) | vers:all/* |
| Siemens | SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) | vers:all/* |
| Siemens | SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) | vers:all/* |
| Siemens | SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) | vers:all/* |
| Siemens | SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) | vers:all/* |
| Siemens | SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) | vers:all/* |
| Siemens | SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) | vers:all/* |
| Siemens | SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) | vers:all/* |
| Siemens | SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) | vers:all/* |
| Siemens | SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) | vers:all/* |
| Siemens | SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) | vers:all/* |
| Siemens | SCALANCE SC622-2C (6GK5622-2GS00-2AC2) | vers:all/* |
| Siemens | SCALANCE SC626-2C (6GK5626-2GS00-2AC2) | vers:all/* |
| Siemens | SCALANCE SC632-2C (6GK5632-2GS00-2AC2) | vers:all/* |
| Siemens | SCALANCE SC636-2C (6GK5636-2GS00-2AC2) | vers:all/* |
| Siemens | SCALANCE SC642-2C (6GK5642-2GS00-2AC2) | vers:all/* |
| Siemens | SCALANCE SC646-2C (6GK5646-2GS00-2AC2) | vers:all/* |
| Siemens | SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) | vers:all/* |
| Siemens | SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) | vers:all/* |
| Siemens | SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) | vers:all/* |
| Siemens | SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) | vers:all/* |
| Siemens | SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) | vers:all/* |
| Siemens | SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) | vers:all/* |
| Siemens | SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) | vers:all/* |
| Siemens | SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) | vers:all/* |
| Siemens | SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) | vers:all/* |
| Siemens | SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) | vers:all/* |
| Siemens | SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) | vers:all/* |
| Siemens | SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) | vers:all/* |
| Siemens | SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) | vers:all/* |
| Siemens | SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) | vers:all/* |
| Siemens | SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) | vers:all/* |
| Siemens | SCALANCE X200-4P IRT (6GK5200-4AH10-2BA3) | vers:all/* |
| Siemens | SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3) | vers:all/* |
| Siemens | SCALANCE X201-3P IRT (6GK5201-3BH10-2BA3) | vers:all/* |
| Siemens | SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6) | vers:all/* |
| Siemens | SCALANCE X201-3P IRT PRO (6GK5201-3JR10-2BA6) | vers:all/* |
| Siemens | SCALANCE X202-2IRT (6GK5202-2BB00-2BA3) | vers:all/* |
| Siemens | SCALANCE X202-2IRT (6GK5202-2BB10-2BA3) | vers:all/* |
| Siemens | SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3) | vers:all/* |
| Siemens | SCALANCE X202-2P IRT (6GK5202-2BH10-2BA3) | vers:all/* |
| Siemens | SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6) | vers:all/* |
| Siemens | SCALANCE X202-2P IRT PRO (6GK5202-2JR10-2BA6) | vers:all/* |
| Siemens | SCALANCE X204-2 (6GK5204-2BB10-2AA3) | vers:all/* |
| Siemens | SCALANCE X204-2FM (6GK5204-2BB11-2AA3) | vers:all/* |
| Siemens | SCALANCE X204-2LD (6GK5204-2BC10-2AA3) | vers:all/* |
| Siemens | SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2) | vers:all/* |
| Siemens | SCALANCE X204-2TS (6GK5204-2BB10-2CA2) | vers:all/* |
| Siemens | SCALANCE X204IRT (6GK5204-0BA00-2BA3) | vers:all/* |
| Siemens | SCALANCE X204IRT (6GK5204-0BA10-2BA3) | vers:all/* |
| Siemens | SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6) | vers:all/* |
| Siemens | SCALANCE X204IRT PRO (6GK5204-0JA10-2BA6) | vers:all/* |
| Siemens | SCALANCE X204RNA (HSR) (6GK5204-0BA00-2MB2) | vers:all/* |
| Siemens | SCALANCE X204RNA (PRP) (6GK5204-0BA00-2KB2) | vers:all/* |
| Siemens | SCALANCE X204RNA EEC (HSR) (6GK5204-0BS00-2NA3) | vers:all/* |
| Siemens | SCALANCE X204RNA EEC (PRP) (6GK5204-0BS00-3LA3) | vers:all/* |
| Siemens | SCALANCE X204RNA EEC (PRP/HSR) (6GK5204-0BS00-3PA3) | vers:all/* |
| Siemens | SCALANCE X206-1 (6GK5206-1BB10-2AA3) | vers:all/* |
| Siemens | SCALANCE X206-1LD (6GK5206-1BC10-2AA3) | vers:all/* |
| Siemens | SCALANCE X208 (6GK5208-0BA10-2AA3) | vers:all/* |
| Siemens | SCALANCE X208PRO (6GK5208-0HA10-2AA6) | vers:all/* |
| Siemens | SCALANCE X212-2 (6GK5212-2BB00-2AA3) | vers:all/* |
| Siemens | SCALANCE X212-2LD (6GK5212-2BC00-2AA3) | vers:all/* |
| Siemens | SCALANCE X216 (6GK5216-0BA00-2AA3) | vers:all/* |
| Siemens | SCALANCE X224 (6GK5224-0BA00-2AA3) | vers:all/* |
| Siemens | SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3) | vers:all/* |
| Siemens | SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3) | vers:all/* |
| Siemens | SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3) | vers:all/* |
| Siemens | SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3) | vers:all/* |
| Siemens | SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3) | vers:all/* |
| Siemens | SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3) | vers:all/* |
| Siemens | SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3) | vers:all/* |
| Siemens | SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3) | vers:all/* |
| Siemens | SCALANCE X304-2FE (6GK5304-2BD00-2AA3) | vers:all/* |
| Siemens | SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3) | vers:all/* |
| Siemens | SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3) | vers:all/* |
| Siemens | SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3) | vers:all/* |
| Siemens | SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3) | vers:all/* |
| Siemens | SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3) | vers:all/* |
| Siemens | SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3) | vers:all/* |
| Siemens | SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3) | vers:all/* |
| Siemens | SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3) | vers:all/* |
| Siemens | SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3) | vers:all/* |
| Siemens | SCALANCE X307-3 (6GK5307-3BL00-2AA3) | vers:all/* |
| Siemens | SCALANCE X307-3 (6GK5307-3BL10-2AA3) | vers:all/* |
| Siemens | SCALANCE X307-3LD (6GK5307-3BM00-2AA3) | vers:all/* |
| Siemens | SCALANCE X307-3LD (6GK5307-3BM10-2AA3) | vers:all/* |
| Siemens | SCALANCE X308-2 (6GK5308-2FL00-2AA3) | vers:all/* |
| Siemens | SCALANCE X308-2 (6GK5308-2FL10-2AA3) | vers:all/* |
| Siemens | SCALANCE X308-2LD (6GK5308-2FM00-2AA3) | vers:all/* |
| Siemens | SCALANCE X308-2LD (6GK5308-2FM10-2AA3) | vers:all/* |
| Siemens | SCALANCE X308-2LH (6GK5308-2FN00-2AA3) | vers:all/* |
| Siemens | SCALANCE X308-2LH (6GK5308-2FN10-2AA3) | vers:all/* |
| Siemens | SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3) | vers:all/* |
| Siemens | SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3) | vers:all/* |
| Siemens | SCALANCE X308-2M (6GK5308-2GG00-2AA2) | vers:all/* |
| Siemens | SCALANCE X308-2M (6GK5308-2GG10-2AA2) | vers:all/* |
| Siemens | SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2) | vers:all/* |
| Siemens | SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2) | vers:all/* |
| Siemens | SCALANCE X308-2M TS (6GK5308-2GG00-2CA2) | vers:all/* |
| Siemens | SCALANCE X308-2M TS (6GK5308-2GG10-2CA2) | vers:all/* |
| Siemens | SCALANCE X310 (6GK5310-0FA00-2AA3) | vers:all/* |
| Siemens | SCALANCE X310 (6GK5310-0FA10-2AA3) | vers:all/* |
| Siemens | SCALANCE X310FE (6GK5310-0BA00-2AA3) | vers:all/* |
| Siemens | SCALANCE X310FE (6GK5310-0BA10-2AA3) | vers:all/* |
| Siemens | SCALANCE X320-1 FE (6GK5320-1BD00-2AA3) | vers:all/* |
| Siemens | SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3) | vers:all/* |
| Siemens | SCALANCE X408-2 (6GK5408-2FD00-2AA2) | vers:all/* |
| Siemens | SCALANCE XC316-8 (6GK5324-8TS00-2AC2) | vers:all/* |
| Siemens | SCALANCE XC324-4 (6GK5328-4TS00-2AC2) | vers:all/* |
| Siemens | SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) | vers:all/* |
| Siemens | SCALANCE XC332 (6GK5332-0GA00-2AC2) | vers:all/* |
| Siemens | SCALANCE XC416-8 (6GK5424-8TR00-2AC2) | vers:all/* |
| Siemens | SCALANCE XC424-4 (6GK5428-4TR00-2AC2) | vers:all/* |
| Siemens | SCALANCE XC432 (6GK5432-0GR00-2AC2) | vers:all/* |
| Siemens | SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2) | vers:all/* |
| Siemens | SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2) | vers:all/* |
| Siemens | SCALANCE XF204 (6GK5204-0BA00-2AF2) | vers:all/* |
| Siemens | SCALANCE XF204-2 (6GK5204-2BC00-2AF2) | vers:all/* |
| Siemens | SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2) | vers:all/* |
| Siemens | SCALANCE XF204IRT (6GK5204-0BA00-2BF2) | vers:all/* |
| Siemens | SCALANCE XF204IRT (6GK5204-0BA10-2BF2) | vers:all/* |
| Siemens | SCALANCE XF206-1 (6GK5206-1BC00-2AF2) | vers:all/* |
| Siemens | SCALANCE XF208 (6GK5208-0BA00-2AF2) | vers:all/* |
| Siemens | SCALANCE XR302-32 (6GK5334-5TS00-2AR3) | vers:all/* |
| Siemens | SCALANCE XR302-32 (6GK5334-5TS00-3AR3) | vers:all/* |
| Siemens | SCALANCE XR302-32 (6GK5334-5TS00-4AR3) | vers:all/* |
| Siemens | SCALANCE XR322-12 (6GK5334-3TS00-2AR3) | vers:all/* |
| Siemens | SCALANCE XR322-12 (6GK5334-3TS00-3AR3) | vers:all/* |
| Siemens | SCALANCE XR322-12 (6GK5334-3TS00-4AR3) | vers:all/* |
| Siemens | SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2) | vers:all/* |
| Siemens | SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2) | vers:all/* |
| Siemens | SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2) | vers:all/* |
| Siemens | SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2) | vers:all/* |
| Siemens | SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2) | vers:all/* |
| Siemens | SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2) | vers:all/* |
| Siemens | SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2) | vers:all/* |
| Siemens | SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2) | vers:all/* |
| Siemens | SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2) | vers:all/* |
| Siemens | SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG10-3AR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG10-3HR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2) | vers:all/* |
| Siemens | SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG10-1AR2) | vers:all/* |
The advisory lists more products than DeSpy shows.
DeSpy has not checked any unit, hardware revision or firmware.
Vulnerabilities in this advisory
- CVE-2025-15467 — CVE-2025-15467 · CWE-787
Issue summary: Parsing CMS AuthEnvelopedData or EnvelopedData message with maliciously crafted AEAD parameters can trigger a stack buffer overflow. Impact summary: A stack buffer overflow may lead to a crash, causing Denial of Service, or potentially remote code execution. When parsing CMS (Auth)EnvelopedData structures that use AEAD ciphers such as AES-GCM, the IV (Initialization Vector) encoded in the ASN.1 parameters is copied into a fixed-size stack buffer without verifying that its length fits the destination. An attacker can supply a crafted CMS message with an oversized IV, causing a stack-based out-of-bounds write before any authentication or tag verification occurs. Applications and services that parse untrusted CMS or PKCS#7 content using AEAD ciphers (e.g., S/MIME (Auth)EnvelopedData with AES-GCM) are vulnerable. Because the overflow occurs prior to authentication, no valid key material is required to trigger it. While exploitability to remote code execution depends on platform and toolchain mitigations, the stack-based write primitive represents a severe risk. The FIPS modules in 3.6, 3.5, 3.4, 3.3 and 3.0 are not affected by this issue, as the CMS implementation is outside the OpenSSL FIPS module boundary. OpenSSL 3.6, 3.5, 3.4, 3.3 and 3.0 are vulnerable to this issue. OpenSSL 1.1.1 and 1.0.2 are not affected by this issue.
Acknowledgments, as the advisory lists them
- Siemens ProductCERT: reported this vulnerability to CISA.
The advisory's legal notice
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Sources
DeSpy's copy of this version is dated 2026-09-28.
This product uses the NVD API but is not endorsed or certified by the NVD.
CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.
CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy.
CISA's Known Exploited Vulnerabilities catalog and CISA Vulnrichment data are CC0 1.0. CISA advisories are shown with the TLP label their document carries. No endorsement by CISA, DHS, NIST or MITRE is stated or implied.